Detection and exclusion of interatrial shunts by two-dimensional echocardiography and peripheral venous injection.

Originally publishedhttps://doi.org/10.1161/01.CIR.59.2.379Circulation. 1979;59:379–384

    Two-dimensional echocardiography (2-D echo) was used with peripherally injected contrast material to detect interatrial shunts in 33 patients. Group 1 consisted of 11 patients having classic clinical findings of atrial septal defect. Group 2 consisted of 12 patients with problems requiring that atrial shunting be excluded. Group 3 (control group) consisted of 10 patients undergoing cardiac catheterization for chest pain. Confirmation of the 2-D echo findings was provided by cardiac catheterization in 32 patients and postmortem examination in one. Right-to-left atrial shunts were detected in all 11 patients in group 1, although seven had no right-to-left shunt calculable by oximetry. Four patients in Group 2 had right-to-left atrial shunts. None of the patients in Group 3 had atrial shunts. In the 15 patients with atrial shunts, the degree of right-to-left shunting could be qualitatively assessed as small, moderate, or large. There were no false-negative or false-positive results by contrast 2-D echo.

    eLetters(0)

    eLetters should relate to an article recently published in the journal and are not a forum for providing unpublished data. Comments are reviewed for appropriate use of tone and language. Comments are not peer-reviewed. Acceptable comments are posted to the journal website only. Comments are not published in an issue and are not indexed in PubMed. Comments should be no longer than 500 words and will only be posted online. References are limited to 10. Authors of the article cited in the comment will be invited to reply, as appropriate.

    Comments and feedback on AHA/ASA Scientific Statements and Guidelines should be directed to the AHA/ASA Manuscript Oversight Committee via its Correspondence page.